| Part No |
Description |
| Micro and Nano Cables and Converters |
| IC200ACC415 |
RS-232 to RS-485 Converter requires IC200CBL500 or equivalent. |
| IC200CBL500 |
Programming cable (RJ-45 to DB-9 pin) RS-232. 3 Meters. |
| IC200CBL501 |
I/O Expansion cable, 0.1 meter long (Qty 5) |
| IC200CBL505 |
I/O Expansion cable, 0.5 meter long |
| IC200CBL510 |
I/O Expansion cable, 1 meter long |
| Nano (10 Point) non expandable |
| IC200NAL110 |
10 point PLC, (6) 12VDC in, (4) Relay Out, (1) Analog Input (0-10VDC, 8 bit), 12VDC Power Supply |
| IC200NAL211 |
10 point PLC, (6) 24VDC In, (4) Relay Out, (1) Analog Input (0-10VDC, 8 bit), 24VDC Power Supply |
| IC200NDD010 |
10 point PLC, (6) 12VDC In, (4) 12VDC Out, 12VDC Power Supply |
| IC200NDD101 |
10 point (6) DC in, (4) DC Out, DC Power Supply |
| IC200NDR001 |
10 point (6) DC In, (4) Relay Out, DC Power Supply |
| IC200NDR010 |
10 point PLC, (6) 12VDC In, (4) Relay Out, 12VDC Power Supply |
| Nano and Micro Tool Boxes |
| IC200TBX010 |
Tool box, 10 point, (IC200NDR001) DC In/Relay Out, DC Power Supply With software, manuals and cables (IC640VPS002) |
| IC200TBX014 |
Tool box, 14 point, (IC200UDR001) DC In/Relay Out, AC Power Supply With software, manuals and cables (IC640VPS002) |
| IC200TBX023 |
Tool box, 23 point, (IC200UAL006) DC In/Relay Out, 2 analog In, 1 analog out, AC Power Supply With software, manuals and cables (IC640VPS002) |
| IC200TBX028 |
Tool box, 28 point, (IC200UDR005) DC In/Relay Out, AC Power Supply With software, manuals and cables (IC640VPS002) |
| IC200TBX064 |
Tool box, Micro 64 and software. Includes (IC200UDD064) 24VDC In/24VDC Out, DC Power Supply,(IC200USB001) RS-232 option board with (2) 0 -10VDC analog in with Proficy software, manuals and cables (IC646MPM101) |
| IC200TBX110 |
Tool box, 10 point (IC200NDR001) 24VDCIn/Relay Out, 24 P/S, VersaMax DataPanel DP45 with Programming software and cables, (IC640VPS00, IC752DDZ000, IC200CBL555) |
| IC200TBX114 |
Tool box, 14 point (IC200UDR001) 24VDCIn/Relay Out, 24 P/S, VersaMax DataPanel DP45 with Programming software and cables, (IC640VPS00, IC752DDZ000, IC200CBL555) |
| IC200TBX123 |
Tool box, 23 point (IC200UAL006) 24VDCIn/Relay Out, 2 Analog In/1 Analog out, 24 P/S, VersaMax DataPanel DP45 with Programming software and cables, (IC640VPS00, IC752DDZ000, IC200CBL555) |
| IC200TBX128 |
Tool box, 28 point (IC200UDR005) 24VDCIn/Relay Out, 24 P/S, VersaMax DataPanel DP45 with Programming software and cables, (IC640VPS00, IC752DDZ000, IC200CBL555) |
| IC200TBX164 |
Tool box, Micro 64 and software. Includes (IC200UDR164) 24VDC In/Relay Out, AC Power Supply, (IC200USB001) RS-232 option board with (2) 0 -10VDC analog in with Proficy software, manuals and cables (IC646MPM101) |
| IC200TBX210 |
Tool box, 10 point, (IC200NDR001) 24VDC In/Relay Out, requires 24VDC Power, VersaMax SE (IC200SET001) with all software, cables (IC640VPS002)and manuals. |
| IC200TBX214 |
Tool box, 14 point, (IC200UDR001) 24VDC In/Relay Out, requires 120VAC Power, VersaMax SE (IC200SET001) with all software, cables (IC640VPS002)and manuals. |
| IC200TBX223 |
Tool box, 23 point, (IC200UAL006) 24VDC In/Relay Out, requires 120VAC Power, VersaMax SE (IC200SET001) with all software, cables (IC640VPS002)and manuals. |
| IC200TBX228 |
Tool box, 28 point, (IC200UDR005) 24VDC In/Relay Out, requires 120VAC Power, VersaMax SE (IC200SET001) with all software, cables (IC640VPS002)and manuals. |
| OEM Productivity Value Packs - Micro |
| IC200UAA003-24 |
Qty of 24, 14 point PLC, (8) 120VAC In, (6) 120VAC Out, 120V/240VAC Power Supply |
| IC200UAA007-24 |
Qty of 24, 28 point PLC, (16) 120VAC In, (12) 120VAC Out, 120V/240AC Power Supply. Battery (IC200ACC403) is required for data retention |
| IC200UAL005-24 |
Qty of 24, 23 point PLC, (13) 24VDC In, (1) 24VDC Out, (9) Relay Out, (2) Analog In & (1) Analog Out, 24VDC Power Supply. Battery (IC200ACC403) is required for long-term data retention & Real Time Clock |
| IC200UAL006-24 |
Qty of 24, 23 point PLC< (13) 24VDC In, (9) Relay Out, (1) 24VDC Out, (2) Analog In & (1) Analog Out, 120V/240AC Power Supply. Battery (IC200ACC403) is required for dtat retention. Battery not included. |
| IC200UAR014-24 |
Qty of 24, 14 point PLC, (8) 120VAC In, (6) Relay Out (2 at 10 amp & 4 at 2 amp), 120V/240VAC Power Supply |
| IC200UAR028-24 |
Qty of 24, 28 point PLC< (16) 120VAC In, (12) Relay Out (2 at 10 amp & 10 at 2 amp), 120V/240AC Power Supply. Battery (IC200ACC403) is required for data retention. Battery not included. |
| IC200UDD110-24 |
Qty of 24, 28 point PLC, (16) 24VDC In, (12) 24VDC Out (6) 1.0A, (6) 0.5A, 24VDC Power Supply. Battery (IC200ACC403) is required for data retention. |
| IC200UDR001-24 |
Qty of 24, 14 point PLC, (8) 24VDC In, (6) Relay Out, 120V/240 AC Power Supply |
| IC200UDR002-24 |
Qty of 24, 14 point PLC, (8) 24VDC In, (6) Relay Out, 24 VDC Power Supply |
| IC200UDR005-24 |
Qty of 24, 28 point PLC, (16) 24VDC In, (11) Relay Out, (1) 24VDC Out, 120V/240AC Power Supply |
| IC200UDR010-24 |
Qty of 24, 28 point PLC, (16) 24VDC In, (11) Relay Out, (1) 24VDC Out, 24VDC Power Supply |
| OEM Productivity Value Packs-Analog Expansion Unit |
| IC200UEX626-24 |
Qty of 24, 6 channel Analog expansion. (4) Analog inputs & (2) Analog Outputs, 24VDC Power Supply (includes IC200CBL501) |
| IC200UEX636-24 |
Qty of 24, 6 channel Analog expansion. (4) Analog inputs & (2) Analog outputs. 120/240 |
| OEM Productivity Value Packs-Discrete Expansn Unit |
| IC200UEX009-24 |
Qty of 24, 14 point expansion. (8) 120VAC In, (6) Relay Out (2 at 10 amp & 4 at 2 amp), 120/240VAC Power Supply (includes IC200CBL501) |
| IC200UEX010-24 |
Qty of 24, 14 point expansion. (8) 120VAC In, (6) 120VAC Out, 120/240VAC Power Supply (includes IC200CBL501) |
| IC200UEX011-24 |
Qty of 24, 14 point expansion. (8) 24VDC In, (6) Relay Out, 120V/240AC Power Supply (includes IC200CBL501) |
| IC200UEX012-24 |
Qty of 24, 14 point expansion. (8) 24VDC In, (6) Relay Out, 24VDC Power Supply (includes IC200CBL501) |
| IC200UEX209-24 |
Qty of 24, 28 point expansion. (16) 120VAC In, (12) Relay Out (2 at 10 amp & 10 at 2 amp), 120/240VAC Power Supply (includes Ic200CBL501) |
| IC200UEX210-24 |
Qty of 24, 28 point expansion. (16) 120VAC In, (12) 120VAC Out, 120/240VAC Power Supply (includes IC200CBL501) |
| IC200UEX211-24 |
Qty of 24, 28 point expansion. (16) 24VDC In, (12) Relay Out, 120V/240AC Power Supply (includes IC200CBL501) |
| IC200UEX212-24 |
Qty of 24, 28 point expansion. (16) 24VDC In, (12) Relay Out, 24VDC Power Supply (includes IC200CBL501) |
| VersaMax |
| IC200NAL211-24 |
Qty 24, 10 point PLC, (6) 24VDC in, (4) Relay Out, (1) Analog Input (0-10VDC, 8 bit), 24VDC Power Supply |
| IC200NDR001-24 |
Qty 24, 10 point PLC, (6) 24VDC In, (4) Relay Out, 24VDC Power Supply |
| VersaMax Data Panels |
|
| IC200CBL550 |
Communications cable (RJ-45 to DB-9 pin RS-232, 2 Meters) between VersaMax Micro/Nano and VersaMax DP 20 only |
| IC200CBL555 |
Communications cable (RJ-45 to DB-9 pin RS-232, 2 meters) for VersaMax DP 45, 65 and 85 |
| IC200DTX200 |
Operator Interface for changing timer/counter/register values. 2 x 16 character LCD backlight display and 6 operation keys. No stored messaging, PLC stores messages. |
| IC200DTX450 |
Operator Interface with up to 200 stored messages. 2 x 16 character LCD backlight display and 6 function keys |
| IC200DTX650 |
Operator Interface with up to 200 stored messages. 4 x 16 character LCD backlight display and 8 function keys. |
| IC200DTX850 |
Operator Interface with up to 200 stored messages. 4 x 20 character LCD backlight display, 8 function keys and numeric keypad |
| VersaMax Micro (14 Point) |
| IC200UAA003 |
14 point (8) AC In, (6) AC Out, AC Power Supply |
| IC200UAR014 |
14 point PLC, (8) 120VAC In, (6) Relay Out (2 at 10 amp and 4 at 2 amp), 120V/240VAC Power Supply |
| IC200UDD104 |
14 point (8) 24VDC In, (6) 24VDC Out (2) 1.0 A, (4) 0.5A, 24VDC Power Supply |
| IC200UDD112 |
14 point PLC,(8) 12VDC In, (6) 12VDC Out at 0.70 A, 12VDC Power Supply |
| IC200UDR001 |
14 point (8) 24VDC In, (6) Relay Out, AC Power Supply |
| IC200UDR002 |
14 point (8) 24VDC In, (6) Relay Out, 24VDC Power Supply |
| IC200UDR003 |
14 point PLC, (8) 12VDC In, (6) Relay Out, 12VDC Power Supply |
| VersaMax Micro (28 Point) |
| IC200UAA007 |
28 point; (16) AC In, (12) AC Out, AC Power Supply. Battery (IC200ACC403) is required for data retention. Battery not included. |
| IC200UAR028 |
28 point PLC,(16) 120VAC In, (12) Relay Out (2 at 10 amp and 10 at 2 amp) 120V/240AC Power Supply. Battery (IC200ACC403) is required for data retention. Battery not included. |
| IC200UDD110 |
28 point; (16) 24VDC In, (12) 24VDC Out (6) 1.0 A, (6) 0.5A, 24VDC Power Supply. Battery (IC200ACC403) is required for data retention. Battery not included. |
| IC200UDD120 |
28 point PLC,(16) 24VDC In, (12) 24VDC Out ESCP(2 at 1.0 amp and 10 at 0.70 amp), 24VDC Power Supply. Battery (IC200ACC403) is required for data retention. Battery not included. |
| IC200UDD212 |
28 point PLC,(16) 12VDC In, (12) 12VDC Out 0.70 A, 12VDC Power Supply. Battery (IC200ACC403) is required for data retention. Battery not included. |
| IC200UDR005 |
28 point; (16) 24VDC In, (11) Relay Out, (1) 24VDC Out, AC Power Supply. Battery (IC200ACC403) is required for data retention. Battery not included. |
| IC200UDR006 |
28 point PLC, (16) 12VDC In, (1) 12VDC Out, (11) Relay Out, 12VDC Power Supply. Battery (IC200ACC403) is required for long term data rentntion and Real Time Clock. Battery not included. |
| IC200UDR010 |
28 point; (16) 24VDC In, (11) Relay Out, (1) 24VDC Out, 24VDC Power Supply. Battery (IC200ACC403) is required for data retention. Battery not included. |
| VersaMax Micro 64 points |
| IC200UDD064 |
VersaMax Micro 64 point PLC,(40) 24VDC In, (24) 24VDC source Out ESCP, 24VDC Power Supply. (1) serial port and (1)optional communication port. |
| IC200UDD164 |
VersaMax Micro 64 point PLC,(40) 24VDC In, (24) 24VDC Sink Output, 24VDCpower supply. (1) serial port and (1)optional communication port. |
| IC200UDR064 |
VersaMax Micro 64 point PLC,(40) 24VDC In, (24) Relay Out, 24VDC Power Supply. (1) serial port and (1)optional communication port. |
| IC200UDR164 |
VersaMax Micro 64 point PLC,(40) 24VDC In, (24) Relay Out, 115/240VAC Power Supply. (1) serial port and (1)optional communication port. |
| VersaMax Micro Accessories |
| IC200ACC402 |
Removable Terminal Strips, 10 per pack |
| IC200ACC403 |
Battery for 23 and 28 point Micro for data retention |
| IC200ACC404 |
Spare parts kit. Two terminal strips and four plastic doors and four covers |
| IC200ACC414 |
The ACC414 is a long term battery for the VersaMax Micro 23/28 point CPUs. The battery will backup upto 7 years. Marketing Mailing N -06-03-16 |
| IC200ACC450 |
Simulator for VersaMax Nano. 6 Inputs |
| IC200ACC451 |
Simulator for VersaMax Micro 8 Inputs |
| IC200KIT001 |
The kit includes VersaPro (IC640VPS002), CAD files, programming cable, manuals and other tools to aid in the conversion process from Series 90 Micro to VersaMax Micro. |
| IC200UMB001 |
VersaMax Micro 64, User Program Memory Module. Compatible with VersaMaxMicro 64 only. |
| IC200USB001 |
VersaMax Micro 64, RS-232 communications option board with (2) 0 - 10VDCanalog input channels built-in. The option board also supports program storage memory module. Compatible with VersaMax Micro 64 only. |
| IC200USB002 |
VersaMax Micro 64, RS-485 communications option board with (2) 0 - 10VDCanalog input channels built-in. The option board also supports program storage memory module. Compatible with VersaMax Micro 64 only. |
| IC200UUB001 |
VersaMax Micro 64, USB Slave communications option board. The option board also supports program storage memory module. Compatible with VersaMax Micro 64 only. |
| VersaMax Micro Expansion |
| IC200UEC008 |
VersaMax Micro Expansion 8 point combination (4) 24VDC In, (4) 24VDC Output Source with ESCP, 24VDC Power Supply (includes IC200CBL501). |
| IC200UEC108 |
VersaMax Micro Expansion 8 point combination (4) 24VDC In, (4) 24VDC Output Source, SNK Out Expansion, 24DCPS |
| IC200UEC208 |
VersaMax Micro Expansion 8 point combination (4) 24VDC In, (4) Relay Output, 24VDC Power Supply (includes IC200CBL501). |
| IC200UEI008 |
VersaMax Micro Expansion 8 point (8) 24VDC In, 24VDC Power Supply (includes IC200CBL501). |
| IC200UEI016 |
VersaMax Micro Expansion 16 point Input (16) 24VDC In, 24VDC Power Supply (includes IC200CBL501). |
| IC200UEO008 |
VersaMax Micro Expansion 8 Output Expansion (8) 24VDC Outputs with ESCP, 24VDC Power Supply (includes IC200CBL501) |
| IC200UEO016 |
VersaMax Micro Expansion 16 point (16) 24VDC Source ESCP Outputs, 24VDC Power Supply (includes IC200CBL501) |
| IC200UEO108 |
VersaMax Micro Expansion 8 Output Expansion 24VDC Sink Output, 24VDC Power Supply (includes IC200CBL501) |
| IC200UEO116 |
VersaMax Micro Expansion 16 Output Expansion (16) 24VDC Sink Outputs, 24VDC Power Supply (includes IC200CBL501) |
| IC200UER008 |
VersaMax Micro Expansion 8 Output Expansion (8) Relay Outputs, 24VDC Power Supply (includes IC200CBL501) |
| IC200UER016 |
VersaMax Micro Expansion 16 Output Expansion (16) Relay Outputs, 24VDC Power Supply (includes IC200CBL501). |
| IC200UEX009 |
14 point expansion. (8) 120VAC In, (6) Relay Out (2 at 10 amp and 4 at 2 amp), 120/240VAC Power Supply. (includes IC200CBL501) |
| IC200UEX010 |
14 point expansion. (8) 120VAC In, (6) 120VAC Out, 120/240VAC Power Supply. (includes IC200CBL501) |
| IC200UEX011 |
14 point (8) 24VDC In, (6) Relay Out, AC Power Supply (includes IC200CBL501) |
| IC200UEX012 |
14 point (8) 24VDC In, (6) Relay Out, DC Power Supply (includes IC200CBL501) |
| IC200UEX013 |
14 point Exp.(8) 12VDC In, (6) Relay Out, 12VDC Power Supply (includes IC200CBL501) |
| IC200UEX014 |
14 point (8) 24VDC In, (6) DC Out, DC Power Supply (includes IC200CBL501) |
| IC200UEX015 |
14 point Exp (8) 12VDC In, (6)12VDC Out, 12VDC Power Supply (includes IC200CBL501) |
| IC200UEX122 |
14 point Exp (8) 24VDC In, (6)24V DC Out with ESCP, 24VDC Power Supply (includes IC200CBL501) |
| IC200UEX209 |
28 point expansion. (16) 120VAC In, (12) Relay Out (2 @ 10 amp & 10 @ 2 amp), 120/240VAC Power Supply. (includes IC200CBL501) |
| IC200UEX210 |
28 point expansion. (16) 120VAC In, (12) 120VAC Out, 120/240VAC Power Supply. (Includes IC200CBL501) |
| IC200UEX211 |
28 point expansion. (16) 24VDC In, (12) Relay Out, 120V/240AC Power Supply (includes IC200CBL501) |
| IC200UEX212 |
28 point expansion. (16) 24VDC In, (12) Relay Out, 24VDC Power Supply (included IC200CBL501) |
| IC200UEX213 |
28 point expansion. (16) 12VDC In, (12) Relay Out, 12VDC Power Supply (included IC200CBL501) |
| IC200UEX214 |
28 point expansion. (16) 24VDC In, (12) 24VDC Out, 24VDC Power Supply (includes IC200CBL501) |
| IC200UEX215 |
28 point expansion. (16) 12VDC In, (12) 12 VDC Out, 12VDC Power Suppy (includes IC200CBL501) |
| IC200UEX222 |
28 point expansion. (16) 24VDC In, (12) 24VDC Out with ESCP, 24VDC Power Supply (includes IC200CBL501) |
| IC200UEX616 |
6 channel Analog expansion. (4) Analog inputs & (2) Analog outputs, 12VDC Power Supply (includes IC200CBL501) |
| IC200UEX626 |
6 channel Analog expansion. (4) Analog inputs & (2) Analog Outputs, 24VDC Power Supply (*includes IC200CBL501) |
| IC200UEX636 |
6 channel Analog expansion. (4) Analog inputs & (2) Analog outputs. 120/240 VAC Power Supply (includes IC200CBL501) |
| IC200UEX724 |
RTD expansion module for VersaMax Micro Pt 100, -100 to +600 C-150 to +1050 F 2 and 3 wire support. Channel update is 141/563 ms (selectable) for all channels |
| IC200UEX726 |
RTD expansion module for VersaMax Micro Pt 100, -100 to +600 C-150 to +1050 F 2 and 3 wire support and 2 analog output voltage and current. |
| IC200UEX734 |
RTD expansion module for VersaMax Micro Pt 100, -100 to +600 C-150 to +1050 F 2 and 3 wire support. Channel update is 141/563 ms (selectable) for all channels |
| IC200UEX736 |
RTD expansion module for VersaMax Micro Pt 100, -100 to +600 C-150 to +1050 F 2 and 3 wire support and 2 analog output voltage and current. |
| VersaMax Micro with Analog |
| IC200UAL004 |
23 point PLC, (13) 12VDC In, (1) 12VDC Out, (9) Relay Out, 12VDC Power Supply, Battery (IC200ACC403) is required for long term data rentntion and Real Time Clock. Battery not included. |
| IC200UAL005 |
23 point PLC, (13) 24VDC In, (1) 24VDC Out, (9) Relay Out, 24VDC Power Supply, Battery (IC200ACC403) is required for long term data rentntion and Real Time Clock. Battery not included. |
| IC200UAL006 |
23 point; (13) 24VDC In, (9) Relay Out, (1) 24VDC Out, (2) Analog In and (1) Analog Out, AC Power Supply. Battery (IC200ACC403) is required for data retention. Battery not included. |